ISO 26262-4: Technical Safety Concept (TSC)

Field Value
Document ID FOX-SAF-TSC-001
Applicable Standard ISO 26262:2018 Part 4 — Product Development: System Level
System foxBMS 2 Battery Management System v1.10.0
Item Definition Li-ion BMS: 1 string, 1 module, 18s1p, NMC cells 3500 mAh
Date 2026-03-21
Status Released for Review
Related Documents FOX-SAF-HARA-001, FOX-SAF-FSC-001, FOX-SAF-FMEA-001

1 Scope

This Technical Safety Concept (TSC) maps each functional safety requirement from the FSC (FOX-SAF-FSC-001) to specific hardware and software elements in the foxBMS 2 system. For each safety mechanism, the document identifies:


2 System Architecture Overview

2.1 Hardware Safety Path

┌──────────┐    SPI     ┌──────────┐   GPIO/SPI   ┌──────────────┐
│  Battery  │◄─────────►│   AFE     │◄────────────►│              │
│  Cells    │  (voltage, │ (LTC681x) │              │              │
│  18s1p    │   temp)    └──────────┘              │  TMS570       │
│           │                                      │  Micro-       │
│           │            ┌──────────┐    CAN       │  controller   │
│           │◄──────────►│  IVT     │◄────────────►│              │
│  Current  │  (shunt)   │ Current  │              │  (ARM Cortex  │
│  path     │            │ Sensor   │              │   R4F, dual   │
│           │            └──────────┘              │   core,       │
│           │                                      │   lockstep)   │
└─────┬─────┘            ┌──────────┐   SPI       │              │
      │                  │  SPS     │◄────────────►│              │
      │    ┌──────────┐  │  Smart   │              │              │
      ├───►│Contactor  │◄─┤  Power   │              │              │
      │    │String +   │  │  Switch  │              │              │
      │    └──────────┘  └──────────┘              │              │
      │    ┌──────────┐                            │              │
      ├───►│Contactor  │◄──────────────────────────┤              │
      │    │String -   │  (via SPS)                │              │
      │    └──────────┘                            │              │
      │    ┌──────────┐                            │              │
      └───►│Precharge  │◄──────────────────────────┤              │
           │Contactor  │  (via SPS)                │              │
           └──────────┘                            │              │
                                                   │              │
           ┌──────────┐   SPI                      │              │
           │  SBC     │◄──────────────────────────►│              │
           │ (FS8x)   │  watchdog, Vdd, RSTB       │              │
           └──────────┘                            └──────┬───────┘
                                                          │
           ┌──────────┐   GPIO                            │
           │Interlock │◄──────────────────────────────────┘
           │Loop      │
           └──────────┘

2.2 Software Safety Path

Sensor Acquisition → SOA Check → DIAG Handler → BMS State Machine → Contactor Control
     (1ms/10ms)       (10ms)       (10ms)           (10ms)              (10ms)

Detailed call chain: 1. AFE driver acquires cell voltages and temperatures (1 ms task triggers SPI transaction, results available within 1–3 ms) 2. SOA_CheckCellVoltage() / SOA_CheckTemperatures() / SOA_CheckCurrent() called from 10 ms task context 3. SOA check compares measured value against MOL/RSL/MSL thresholds from soa_cfg.c 4. If MSL threshold violated: DIAG_Handler(DIAG_ID_xxx_MSL, DIAG_EVENT_NOT_OK, ...) called 5. DIAG_Handler() increments threshold counter for the DIAG ID 6. When counter reaches configured threshold: FATAL flag set, callback function executed 7. Callback (e.g., DIAG_ErrorOvervoltage()) may perform additional actions 8. BMS_Trigger() calls DIAG_IsAnyFatalErrorSet() every 10 ms 9. If any FATAL flag is set: BMS transitions from current state to BMS_STATEMACHINE_ERROR 10. Error state handler commands all contactors open via CONT_OpenContactor() → SPS driver


3 Technical Safety Requirements

3.1 TSR-01: Cell Overvoltage Detection and Reaction (FSR-01
↑ Traces Up
SG-01
, ASIL D)

3.1.1 Detection Mechanism

Parameter Value
Sensor AFE (LTC681x family) — per-cell voltage measurement
Measurement range 0–5000 mV, 16-bit ADC resolution (~0.1 mV/LSB)
Measurement rate Every AFE conversion cycle (~1–3 ms per complete scan of 18 cells)
SOA Check Function SOA_CheckCellVoltage() in soa_cfg.c
MSL Threshold 2800 mV (BC_VOLTAGE_MAX_MSL in battery_cell_cfg.h)
DIAG ID DIAG_ID_CELL_VOLTAGE_OVERVOLTAGE_MSL
DIAG Threshold 50 consecutive events
DIAG Delay 200 ms
DIAG Severity FATAL
Callback DIAG_ErrorOvervoltage

3.1.2 Reaction Chain

  1. SOA_CheckCellVoltage() detects cell_voltage > 2800 mV
  2. Calls DIAG_Handler(DIAG_ID_CELL_VOLTAGE_OVERVOLTAGE_MSL, DIAG_EVENT_NOT_OK, ...)
  3. DIAG increments threshold counter (0 → 1 → ... → 50)
  4. After 50 consecutive NOT_OK events (500 ms at 10 ms period): threshold reached
  5. 200 ms debounce delay elapses
  6. FATAL flag set for DIAG_ID_CELL_VOLTAGE_OVERVOLTAGE_MSL
  7. DIAG_ErrorOvervoltage() callback executed (sets SOF flags, updates CAN signals)
  8. Next BMS_Trigger() call: DIAG_IsAnyFatalErrorSet() returns true
  9. BMS transitions to BMS_STATEMACHINE_ERROR
  10. Error state opens string+, string-, and precharge contactors via SPS

3.1.3 Timing Budget

Phase Duration Source
Sensor acquisition 1–3 ms AFE SPI transaction time
SOA check execution <1 ms Software comparison (negligible)
Threshold accumulation 500 ms 50 × 10 ms task period
Debounce delay 200 ms diag_cfg.c delay_ms
BMS state transition 10 ms Next BMS_Trigger cycle
Contactor command <1 ms SPS SPI write
Contactor mechanical 20–50 ms Relay/contactor opening time
Total FTTI ~750 ms Detection + reaction + actuation

3.1.4 Hardware Elements in Safety Path

Element Function Failure Mode Covered By
AFE (LTC681x) Cell voltage measurement DIAG_ID_AFE_SPI, AFE_COMMUNICATION_INTEGRITY, AFE_MUX, AFE_CONFIG
SPI Bus (AFE) Data transport AFE ↔ MCU DIAG_ID_AFE_SPI (CRC check)
TMS570 MCU SOA comparison, DIAG logic, BMS SM DIAG_ID_SYSTEM_MONITORING, SBC watchdog, lockstep CPU
SPS Driver Contactor power switching SPS feedback (implicit)
Contactors Current path interruption DIAG_ID_STRING_*_CONTACTOR_FEEDBACK
SBC (FS8x) Watchdog, power supply supervision DIAG_ID_SBC_RSTB_ERROR

3.1.5 Redundancy Analysis (ASIL D Requirement)

For ASIL D, ISO 26262 requires independence of safety mechanisms. The following redundancy is provided:


3.2 TSR-02: Cell Undervoltage Detection and Reaction (FSR-02
↑ Traces Up
SG-02
, ASIL C)

3.2.1 Detection Mechanism

Parameter Value
Sensor AFE — per-cell voltage measurement
MSL Threshold 1500 mV (BC_VOLTAGE_MIN_MSL in battery_cell_cfg.h)
DIAG ID DIAG_ID_CELL_VOLTAGE_UNDERVOLTAGE_MSL
DIAG Threshold 50 consecutive events
DIAG Delay 200 ms
Callback DIAG_ErrorUndervoltage

3.2.2 Reaction Chain

Identical structure to TSR-01 with undervoltage-specific callback: 1. SOA_CheckCellVoltage() detects cell_voltage < 1500 mV 2. DIAG threshold counter accumulates 50 events over 500 ms 3. 200 ms debounce delay 4. FATAL flag → BMS ERROR → contactors open

3.2.3 Timing Budget

Phase Duration Total FTTI
Threshold accumulation 500 ms
Debounce delay 200 ms
Actuation 50 ms
Total 750 ms

3.3 TSR-03: Deep Discharge Detection (FSR-03
↑ Traces Up
SG-03
, QM)

Parameter Value
DIAG ID DIAG_ID_DEEP_DISCHARGE_DETECTED
DIAG Threshold 1 event (immediate trigger)
DIAG Delay 100 ms
Detection Deep discharge flag set by cell monitoring logic when cell voltage is critically low (well below UV cutoff) or when cell SOC indicates irreversible state
Reaction Single event → FATAL → BMS ERROR → contactors open
FTTI 10 ms + 100 ms + 50 ms = 160 ms

3.4 TSR-04: Overcurrent Discharge Detection (FSR-04
↑ Traces Up
SG-04
, ASIL B)

3.4.1 Detection Mechanism

Parameter Value
Sensor IVT current sensor (Isabellenhuette) via CAN
Cell-level DIAG ID DIAG_ID_OVERCURRENT_DISCHARGE_CELL_MSL
Cell-level limit 180000 mA (BC_CURRENT_MAX_DISCHARGE_MSL)
String-level DIAG ID DIAG_ID_STRING_OVERCURRENT_DISCHARGE_MSL
String-level limit 2400 mA (BS_MAX_DISCHARGE_CURRENT_MSL)
Pack-level DIAG ID DIAG_ID_PACK_OVERCURRENT_DISCHARGE_MSL
DIAG Threshold 10 consecutive events (all levels)
DIAG Delay 100 ms (all levels)
Callback DIAG_ErrorOvercurrentDischarge

3.4.2 Timing Budget

Phase Duration Notes
IVT measurement ~1 ms Current sensor conversion time
CAN transmission ~1 ms CAN message latency
SOA check <1 ms Software comparison
Threshold accumulation 100 ms 10 × 10 ms task period
Debounce delay 100 ms diag_cfg.c delay_ms
Actuation 50 ms Contactor opening
Total FTTI ~250 ms

3.4.3 Hardware Elements

Element Function Safety Relevance
IVT Shunt Current-to-voltage conversion Primary current measurement
IVT Electronics ADC, CAN transmission Signal conditioning
CAN Bus IVT ↔ MCU data transport DIAG_ID_CAN_TIMING monitors bus health
TMS570 MCU SOA comparison, DIAG logic Processing
SPS + Contactors Current path interruption Actuation

3.5 TSR-05: Overcurrent Charge Detection (FSR-05
↑ Traces Up
SG-05
, ASIL C)

Parameter Value
Cell-level DIAG ID DIAG_ID_OVERCURRENT_CHARGE_CELL_MSL
Cell-level limit 180000 mA (BC_CURRENT_MAX_CHARGE_MSL)
String-level DIAG ID DIAG_ID_STRING_OVERCURRENT_CHARGE_MSL
String-level limit 2400 mA (BS_MAX_CHARGE_CURRENT_MSL)
Pack-level DIAG ID DIAG_ID_PACK_OVERCURRENT_CHARGE_MSL
DIAG Threshold 10 consecutive events
DIAG Delay 100 ms
Callback DIAG_ErrorOvercurrentCharge
FTTI 100 ms + 100 ms + 50 ms = 250 ms

Detection and reaction chain identical to TSR-04 with charge-direction sign convention.


3.6 TSR-06: Overtemperature Detection (FSR-06
↑ Traces Up
SG-06
, ASIL C)

3.6.1 Detection Mechanism

Parameter Value
Sensor 8× NTC thermistors connected via AFE multiplexer
Charge OT DIAG ID DIAG_ID_TEMP_OVERTEMPERATURE_CHARGE_MSL
Charge OT limit 45 °C
Discharge OT DIAG ID DIAG_ID_TEMP_OVERTEMPERATURE_DISCHARGE_MSL
Discharge OT limit 55 °C
DIAG Threshold 500 consecutive events
DIAG Delay 1000 ms
Callback DIAG_ErrorOvertemperatureCharge / DIAG_ErrorOvertemperatureDischarge

3.6.2 Timing Budget

Phase Duration Notes
NTC measurement ~2 ms AFE MUX scan time
Threshold accumulation 5000 ms 500 × 10 ms task period
Debounce delay 1000 ms diag_cfg.c delay_ms
Actuation 50 ms Contactor opening
Total FTTI ~6050 ms (6.05 s)

3.6.3 Rationale for Extended Detection Time

The 500-event threshold with 1000 ms delay (total 6.05 s FTTI) is justified by:

  1. Thermal inertia: Cell temperature change is a slow process. The thermal time constant of a pouch/prismatic cell is typically 30–120 s. Temperature cannot change by more than ~1 °C in 6 s under normal operating conditions.
  2. Noise rejection: NTC measurement through the AFE MUX is susceptible to noise and transient errors. The high threshold count filters out measurement artifacts.
  3. False positive prevention: In automotive environments with rapid ambient temperature changes (e.g., engine bay heat soak after parking), brief temperature excursions should not trigger unnecessary shutdowns.

3.7 TSR-07: Undertemperature Detection (FSR-07
↑ Traces Up
SG-07
, ASIL B)

Parameter Value
Charge UT DIAG ID DIAG_ID_TEMP_UNDERTEMPERATURE_CHARGE_MSL
Discharge UT DIAG ID DIAG_ID_TEMP_UNDERTEMPERATURE_DISCHARGE_MSL
Limit -20 °C (both charge and discharge)
DIAG Threshold 500 consecutive events
DIAG Delay 1000 ms
Callback DIAG_ErrorUndertemperatureCharge / DIAG_ErrorUndertemperatureDischarge
FTTI 5000 ms + 1000 ms + 50 ms = 6050 ms (6.05 s)

Same thermal inertia justification as TSR-06 applies. Ambient temperature changes that would push cell temperature through the -20 °C threshold occur over minutes, not seconds.


3.8 TSR-08: Contactor Feedback Monitoring (FSR-08
↑ Traces Up
SG-08
, ASIL B)

3.8.1 Detection Mechanism

Parameter Value
String- DIAG ID DIAG_ID_STRING_MINUS_CONTACTOR_FEEDBACK
String+ DIAG ID DIAG_ID_STRING_PLUS_CONTACTOR_FEEDBACK
Precharge DIAG ID DIAG_ID_PRECHARGE_CONTACTOR_FEEDBACK
DIAG Threshold 20 consecutive events (all three)
DIAG Delay 100 ms
Detection principle GPIO feedback pin from contactor auxiliary contact compared against SPS commanded state. Mismatch = fault.

3.8.2 Timing Budget

Phase Duration Notes
Feedback GPIO read <1 ms Direct GPIO sampling
Threshold accumulation 200 ms 20 × 10 ms task period
Debounce delay 100 ms diag_cfg.c delay_ms
Actuation 50 ms Open remaining contactors
Total FTTI 350 ms

3.8.3 Welding Detection Logic

The 20-event threshold provides debounce against transient feedback signal glitches (contact bounce, EMC disturbance on feedback wiring). The detection covers two scenarios:

  1. Open-command / closed-feedback (welding): BMS commands contactor open, but feedback indicates it remains closed. This indicates contact welding.
  2. Close-command / open-feedback (sticking open): BMS commands contactor closed, but feedback indicates it remains open. This indicates a mechanical failure or wiring fault.

Both cases result in FATAL flag and ERROR state transition.


3.9 TSR-09: Current Sensor Communication Monitoring (FSR-09
↑ Traces Up
SG-09
, ASIL B)

3.9.1 Detection Mechanism — Multi-Channel Monitoring

Channel DIAG ID Threshold Delay
Main current DIAG_ID_CURRENT_SENSOR_RESPONDING 100 200 ms
Coulomb counting DIAG_ID_CURRENT_SENSOR_CC_RESPONDING 100 2000 ms
Energy counting DIAG_ID_CURRENT_SENSOR_EC_RESPONDING 100 2000 ms
Voltage channel V1 DIAG_ID_CURRENT_SENSOR_V1_MEASUREMENT_TIMEOUT 1 100 ms
Voltage channel V2 DIAG_ID_CURRENT_SENSOR_V2_MEASUREMENT_TIMEOUT 1 100 ms
Voltage channel V3 DIAG_ID_CURRENT_SENSOR_V3_MEASUREMENT_TIMEOUT 1 100 ms

3.9.2 Timing Analysis

Main current channel (critical for overcurrent protection): - T_detection = 100 × 10 ms = 1000 ms - T_reaction = 200 ms - T_actuator = 50 ms - FTTI = 1250 ms

Voltage channels V1/V2/V3 (critical for pack voltage plausibility): - T_detection = 1 × 10 ms = 10 ms - T_reaction = 100 ms - T_actuator = 50 ms - FTTI = 160 ms

Coulomb/Energy counting (critical for SOC accuracy): - T_detection = 100 × 10 ms = 1000 ms - T_reaction = 2000 ms - T_actuator = 50 ms - FTTI = 3050 ms

The longer FTTI for CC/EC channels is acceptable because loss of coulomb counting does not immediately create a hazardous condition — voltage-based SOA checks provide independent protection.


3.10 TSR-10: AFE Communication Monitoring (ASIL D Support)

The AFE is a critical element in the ASIL D safety path for cell voltage and temperature monitoring. Multiple DIAG IDs monitor AFE health:

DIAG ID Failure Mode Threshold Delay
DIAG_ID_AFE_SPI SPI communication failure 5 100 ms
DIAG_ID_AFE_COMMUNICATION_INTEGRITY CRC/PEC error on AFE data 5 100 ms
DIAG_ID_AFE_MUX Temperature MUX failure 5 100 ms
DIAG_ID_AFE_CONFIG AFE register config mismatch 1 100 ms

AFE SPI / Communication Integrity FTTI: - T_detection = 5 × 10 ms = 50 ms - T_reaction = 100 ms - T_actuator = 50 ms - FTTI = 200 ms

AFE Config FTTI: - T_detection = 1 × 10 ms = 10 ms - T_reaction = 100 ms - T_actuator = 50 ms - FTTI = 160 ms

AFE configuration mismatch (threshold=1) triggers on a single detection because it indicates either a register corruption (SEU — Single Event Upset) or a hardware fault that could cause incorrect voltage/temperature readings without detectable communication errors.


3.11 TSR-11: CAN Communication Monitoring

Parameter Value
DIAG ID DIAG_ID_CAN_TIMING
DIAG Threshold 100 consecutive events
DIAG Delay 200 ms
Detection principle CAN message receive timeout. Expected messages from vehicle controller and/or charger not received within configured period.
FTTI 100 × 10 ms + 200 ms + 50 ms = 1250 ms

Loss of CAN communication means the BMS cannot communicate current limits or warnings to the vehicle controller. The BMS treats this as FATAL because the vehicle controller may request currents beyond safe limits without BMS guidance.


3.12 TSR-12: System Monitoring and Flash Integrity

DIAG ID Failure Mode Threshold Delay FTTI
DIAG_ID_SYSTEM_MONITORING RTOS task overrun/hang 1 0 ms ~60 ms
DIAG_ID_FLASHCHECKSUM Flash memory corruption (SEU) 1 0 ms ~60 ms
DIAG_ID_ALERT_MODE SBC alert condition 1 0 ms ~60 ms

These system-level monitors have threshold=1 and no delay because they indicate fundamental integrity failures of the safety platform itself:


3.13 TSR-13: Interlock Loop Monitoring (FSR-10
↑ Traces Up
SG-10
)

Parameter Value
DIAG ID DIAG_ID_INTERLOCK_FEEDBACK
DIAG Threshold 10 consecutive events
DIAG Delay 100 ms
Detection principle Interlock loop current/voltage monitoring via dedicated GPIO or ADC input. Open loop = fault.
FTTI 10 × 10 ms + 100 ms + 50 ms = 250 ms

3.14 TSR-14: SBC Reset Monitoring

Parameter Value
DIAG ID DIAG_ID_SBC_RSTB_ERROR
DIAG Threshold 1 event
DIAG Delay 100 ms
Detection principle SBC RSTB (Reset B) pin state monitoring. If SBC asserts reset, the MCU detects this before reset takes effect and logs the event.
FTTI 1 × 10 ms + 100 ms + 50 ms = 160 ms

3.15 TSR-15: Current on Open String Detection

Parameter Value
DIAG ID DIAG_ID_CURRENT_ON_OPEN_STRING
DIAG Threshold 10 consecutive events
DIAG Delay 100 ms
Detection principle IVT measures non-zero current while all contactors are commanded open. This indicates a welded contactor, an external fault path, or a current sensor offset error.
FTTI 10 × 10 ms + 100 ms + 50 ms = 250 ms

4 Safety Path Timing Summary

TSR DIAG ID(s) Threshold Task (ms) T_detect (ms) Delay (ms) T_act (ms) FTTI (ms)
TSR-01 CELL_VOLTAGE_OVERVOLTAGE_MSL 50 10 500 200 50 750
TSR-02 CELL_VOLTAGE_UNDERVOLTAGE_MSL 50 10 500 200 50 750
TSR-03 DEEP_DISCHARGE_DETECTED 1 10 10 100 50 160
TSR-04 OVERCURRENT_DISCHARGE_*_MSL 10 10 100 100 50 250
TSR-05 OVERCURRENT_CHARGE_*_MSL 10 10 100 100 50 250
TSR-06 TEMP_OVERTEMPERATURE_*_MSL 500 10 5000 1000 50 6050
TSR-07 TEMP_UNDERTEMPERATURE_*_MSL 500 10 5000 1000 50 6050
TSR-08 *_CONTACTOR_FEEDBACK 20 10 200 100 50 350
TSR-09 CURRENT_SENSOR_RESPONDING 100 10 1000 200 50 1250
TSR-10 AFE_SPI / AFE_COMMUNICATION_INTEGRITY 5 10 50 100 50 200
TSR-11 CAN_TIMING 100 10 1000 200 50 1250
TSR-12 SYSTEM_MONITORING / FLASHCHECKSUM 1 1 1 0 50 ~51
TSR-13 INTERLOCK_FEEDBACK 10 10 100 100 50 250
TSR-14 SBC_RSTB_ERROR 1 10 10 100 50 160
TSR-15 CURRENT_ON_OPEN_STRING 10 10 100 100 50 250

5 Hardware Diagnostic Coverage

5.1 AFE Diagnostic Coverage (ASIL D)

Failure Mode Detection Mechanism Coverage
SPI bus stuck/open DIAG_ID_AFE_SPI (timeout/CRC) High
Data corruption DIAG_ID_AFE_COMMUNICATION_INTEGRITY (PEC) High
MUX channel stuck DIAG_ID_AFE_MUX (channel verification) Medium
Register SEU DIAG_ID_AFE_CONFIG (periodic readback) High
ADC offset drift Pack voltage plausibility (AFE vs IVT) Medium
ADC gain drift Pack voltage plausibility (AFE vs IVT) Medium
Open sense wire AFE built-in open-wire detection High

5.2 IVT Diagnostic Coverage (ASIL B)

Failure Mode Detection Mechanism Coverage
CAN communication loss DIAG_ID_CURRENT_SENSOR_RESPONDING High
Current channel failure DIAG_ID_CURRENT_SENSOR_CC_RESPONDING High
Voltage channel failure DIAG_ID_CURRENT_SENSOR_V*_TIMEOUT High
Measurement drift Plausibility (IVT voltage vs AFE sum) Medium

5.3 Contactor Diagnostic Coverage (ASIL B)

Failure Mode Detection Mechanism Coverage
Welding (stuck closed) Contactor feedback vs. SPS command High
Stuck open Contactor feedback vs. SPS command High
Feedback wire broken Current-on-open-string detection Medium
SPS driver failure Contactor feedback (indirect) Medium

5.4 MCU Diagnostic Coverage (ASIL D)

Failure Mode Detection Mechanism Coverage
CPU logic fault TMS570 lockstep (hardware comparator) High
RAM corruption ECC (hardware) + periodic test High
Flash corruption DIAG_ID_FLASHCHECKSUM (CRC) High
Task scheduling fault DIAG_ID_SYSTEM_MONITORING (RTOS check) High
Software hang SBC watchdog (FS8x) High
Power supply fault SBC voltage supervisor → ALERT_MODE High

6 References

Ref Document
[1] ISO 26262:2018 Part 4 — Product Development: System Level
[2] FOX-SAF-HARA-001 — Hazard Analysis and Risk Assessment
[3] FOX-SAF-FSC-001 — Functional Safety Concept
[4] FOX-SAF-FMEA-001 — Software FMEA
[5] FOX-SAF-FTTI-001 — FTTI Calculation Report
[6] foxBMS v1.10.0 src/app/engine/diag/diag_cfg.c
[7] foxBMS v1.10.0 src/app/application/config/battery_cell_cfg.h
[8] foxBMS v1.10.0 src/app/application/config/battery_system_cfg.h
[9] foxBMS v1.10.0 src/app/application/config/soa_cfg.c

Traceability

TSR ID Description Traces Down To
TSR-001
↑ Traces Up
HZ-001
Voltage monitoring SSR-001, SSR-002, SW-REQ-001, SW-REQ-002
↑ Traces Up
SYS-REQ-021TSR-001
TSR-002
↑ Traces Up
HZ-002
Current monitoring SSR-005, SSR-006, SW-REQ-010, SW-REQ-011
↑ Traces Up
SYS-REQ-031TSR-002
TSR-003
↑ Traces Up
HZ-003
Temperature monitoring SSR-007, SSR-008, SSR-009, SW-REQ-020, SW-REQ-021, SW-REQ-022, SW-REQ-023
↑ Traces Up
SYS-REQ-043TSR-003
TSR-004
↑ Traces Up
HZ-004
DIAG threshold SSR-010, SW-REQ-030, SW-REQ-031
TSR-005
↑ Traces Up
HZ-005
↓ Traces Down
SSR-004SW-REQ-044
Contactor control SSR-004, SW-REQ-044
TSR-006
↑ Traces Up
HZ-006
↓ Traces Down
SSR-004SW-REQ-042
Precharge check SSR-004, SW-REQ-042
TSR-007
↑ Traces Up
HZ-007
↓ Traces Down
SSR-010
Interlock monitoring SSR-010
TSR-008
↑ Traces Up
HZ-008
↓ Traces Down
SSR-010SW-REQ-110
CAN timing SSR-010, SW-REQ-110
↓ Traces Down
SSR-040
TSR-009
↑ Traces Up
HZ-009
↓ Traces Down
SSR-010SW-REQ-111
Current sensor SSR-010, SW-REQ-111
↓ Traces Down
SSR-041
TSR-010
↓ Traces Down
SSR-010
SBC watchdog SSR-010
TSR-011
↓ Traces Down
SSR-010
Insulation monitoring SSR-010
TSR-012
↓ Traces Down
SW-REQ-080
Cell balancing SW-REQ-080
↓ Traces Down
UT-080
TSR-013
↑ Traces Up
HZ-010
↓ Traces Down
SW-REQ-070
SOC estimation SW-REQ-070
↓ Traces Down
IT-011UT-070
TSR-014
↓ Traces Down
SSR-003
Redundancy check SSR-003
TSR-015
↓ Traces Down
SSR-003SW-REQ-060
Plausibility check SSR-003, SW-REQ-060

End of Document FOX-SAF-TSC-001